Pole-changing combination
Pole-changing combination 15 kW to 250 kW in switch housing
PU contactor combination in switch housing,
System protection class IP54, dimensions depending on size,
Voltage and power levels
Pole-changing combination for current and starting torque reduction during switch-on by using several power stages (min. two speeds). Controlled starting.
Mains voltage (+10% / -15%)
Mains voltage: 380 to 690 V
Mains frequency: 50 / 60 Hz
Ambient temperature: 0° to + 40° C
Remote controls
Further options and control cabinet equipment according to agreement
EMC Directive 2004/108/EEC
Low Voltage Directive 2006/95/EC
WEEE Directive 2002/96/EC
Control system
Star-delta contactor 15 kW to 250 kW in switch housing
Contactor combination in switch housing, system protection class IP54,
Dimensions depending on size, voltage and power
Starter for current and starting torque reduction at switch-on. Controlled starting.
Mains voltage (+10% / -15%)
Mains voltage: 380 to 690 V
mains frequency: 50 / 60 Hz
Ambient temperature: 0° to + 40° C
Remote controls
Further options and control cabinet equipment according to agreement
EMC Directive 2004/108/EEC
Low Voltage Directive 2006/95/EC
WEEE Directive 2002/96/EC
TSA 7,5 kW up to 250 kW
in switch housing
Soft starter in switch housing, system protection class >= IP54
Dimensions depending on size, voltage and power
Soft starter for digital current and starting torque reduction at power-up. Protected start and stop operation, no switching peak as with star-delta, reliable operation through monitoring, can be used as motor controller
Mains voltage (+10% / -15%)
TSA52-: 200 to 525 V
TSA69-: 200 to 690 V
Mains frequency: 45 to 65 Hz
Three fully controlled phases
Control voltage: 100- 240 V
Ambient temperature: -10° to +40°C (including cabinet heating and hygrostat)
EMC Directive 2004/108/EEC
Low Voltage Directive 2006/95/EC
WEEE Directive 2002/96/EC
FDU 5.5 kW to 200 kW
metal-housing
Frequency inverter in metal housing, system protection class >= IP54
Dimensions depending on size, voltage and power
Controlled start and stop operation, controlled start-up or run-down, stepless fan operation, efficient energy consumption adapted to the air requirement, reliable operation through monitoring, can be used as motor controller
Mains voltage (+10% / -15%)
FDU48-: 380 to 480 V (from 230V on request)
FDU52-: 500 to 525 V – (size B,C,D)
FDU69-: 500 to 690 V – (C69 – F69)
Mains frequency: 45 to 65 Hz
Input power factor: 0.95
Output voltage: 0 to mains voltage
Output frequency: 0 to 400 Hz
Output switching frequency: 3 kHz
Efficiency at nominal load: 98%
Ambient temperature: 0° to +40°C
EMC Directive 2004/108/EEC
Low Voltage Directive 2006/95/EC
WEEE Directive 2002/96/EC
(in outdoor cabinet)
FDU up to 400kW
in outdoor cabinet (OD)
Frequency inverter in cabinet, system protection class >= IP54
Construction site compatible equipment with skids
height: 2,21m
Width: 1.2 to 1.7m
Depth: 0.5 to 0.97m
Controlled start and stop operation, controlled start-up or run-down, stepless fan operation, efficient energy consumption adapted to the air requirement, reliable operation through monitoring, can be used as motor controller
Mains voltage (+10% / -15%)
FDU48-: 380 to 480 V – Size G (2xE), H (2xF)
FDU69-: 500 to 690 V – (on request)
Mains frequency: 45 to 65 Hz
Input power factor: 0.95
Output voltage: 0 to mains voltage
Output frequency: 0 to 400 Hz
Output switching frequency: 3 kHz
Efficiency at nominal load: 98%
Ambient temperature: -10° to +40°C (integrated heating)
EMC Directive 2004/108/EEC
Low Voltage Directive 2006/95/EC
WEEE Directive 2002/96/EC
(in switch cabinet)
FDU up to 3000 kW
in the cabinet
Frequency inverter in control cabinet, system protection class >= IP54
height: 2,35m
Width: 1.2 up to depending on power
depth: 0,6 m
Controlled start and stop operation, controlled start-up or run-down, stepless fan operation, efficient energy consumption adapted to the air requirement, reliable operation through monitoring, can be used as motor controller
Mains voltage (+10% / -15%)
FDU48-: 380 to 480 V –
(from 230V on request)
FDU69-: 500 to 690 V – (from size H69)
Mains frequency: 45 to 65 Hz
Input power factor: 0.95 Output voltage: 0 to line voltage
Output frequency: 0 to 400 Hz
Output switching frequency: 3 kHz
Efficiency at nominal load: 98%
Ambient temperature: -10° to +40°C (Integr. control cabinet heating)
EMC Directive 2004/108/EEC
Low Voltage Directive 2006/95/EC
WEEE Directive 2002/96/EC
Hörder Str. 286, DE-58454 Witten
+49 2302 1702-0
+49 2302 1702-153
info@korfmann.com
Customer oriented and innovative solutions for the health of your employees
Ventilating and Exhausting Systems for:
Our highly qualified expert team of engineers will not only continue to the longstanding tradition of the KORFMANN quality and performance in the field of ventilation for mining and tunneling, underground systems of any kind and industrial sectors, but also increase it to the advantage of your company.
Due to our high affinity for technology, we find the perfect solution for your requirements – no matter in which area. The innovative spirit of our engineers helps us to continuously develop our products and offer you solutions and products also related to industry 4.0.
You can be absolutely certain to have Korfmann Lufttechnik GmbH as a reliable partner at your side. We look forward to convincing you of our efficiency and ability to supply the best product for your future projects.